Error MessageCauseResolution
Oculus Rift failedInternal error in Oculus SDKEnsure the Oculus Rift is connected to the PC and configured correctlyRestart the application
Found -viewconfig command line option but license has not granted EditViewConfig permissionThe application detected an attempt to load a custom view configuration file without the appropriate licenseCustom view configuration requires an Immersive license
Found tracker command line option but license has not granted tracking permissionThe application detected an attempt to load a tracking configuration file without the appropriate licenseCustom tracking configuration requires an Immersive license
Failed to initialise trackerThe application could not configure the tracker from the specified custom tracking configuration fileMake sure the configuration is correctThere should be additional errors in the log describing the exact problem
Failed to create Oculus environmentFailed to create SteamVR environmentFailed to create zSpace environmentFailed to create tracker environmentInternal application error
Failed to read tracker config fileThe XML configuration file provided is invalidMake sure the tracking configuration is valid
No tracker config file path specifiedThe -tracker option was specified on the command line, but no filename followed itSpecify a filename along with the -tracker parameter, e.g. -tracker device.xml
Tracker error: device errorThe tracker device could not be initialised. There may be more information in the error message specific to the deviceEnsure the tracking XML is correct
Tracker error: config not parsedThere were errors in the XML format of the configuration documentEnsure the contents of the tracking XML file are valid XML structures
Tracker error: config emptyThe config XML file is emptyEnsure the tracking XML file has valid configuration in it
Tracker error: config attribute missingThe config XML is missing an attribute that is requiredEnsure the tracking XML is correct
Tracker error: config element missingThe config XML is missing a required elementEnsure the tracking XML is correct
Tracker error: config invalid valueThe config XML specifies an unexpected valueEnsure the tracking XML is correct
ART could not initialize a local data port (no UDP connection)The ART device did not respond to the connection attemptEnsure the IP/Port is correctEnsure DTrack2 configuration is broadcasting to the machine running Visionary Render
--- timeout while waiting for ART tracking dataThe ART device did not respond to a request for dataThe connection to the device may have been lost, or failed to begin with (see above)
--- error while receiving / parsing ART tracking dataThe ART device responded with invalid dataRestart the applicationRestart DTrack2Restart the ART device
ART flystick id is not available [verbose]The tracking configuration specified a flystick body with an ID that does not existEnsure the tracking XML is correctThe correct body ID can be seen in DTrack2
ART flystick id is out of range of the cameras [verbose]The flystick is not visible by any of the ART camerasMove the flystick back into the tracked area
ART body id is not available [verbose]The tracking configuration specified a body with an ID that does not existEnsure the tracking XML is correctThe correct body ID can be seen in DTrack2
ART body id is out of range of the cameras [verbose]The body is not visible by any of the ART camerasMove back into the tracked area
ART: no valid body or flystickThe tracking configuration does not correctly link up to any ART bodies or flysticksEnsure the tracking XML is correct
[warning] Incomplete or badly formatted calibration fileCyberglove calibration data is corrupt or missingRecalibrate the glove
[warning] Could not create directory to save cyberglove calibration /[warning] Could not write cyberglove calibration data to diskThe tracking driver could not save the glove calibration to disk, recalibration will be neededEnsure Documents/VisionaryRender exists and is writable
Failed to connect to serial device on port (mode)The cyberglove driver could not connect to the glove over serialEnsure the glove is connectedEnsure the glove is powered onEnsure the XML configuration specifies the correct serial port (defaults to COM0 if none specified)Ensure the Cyberglove DCU software is not runningEnsure no other application (or other instance of Visionary Render) is connected to the glove
Failed to send stop requestThe cyberglove initialisation attempted to reset the glove ready for new connections, but it failedSee above
Request connection status failedThe cyberglove initialisation failed to query the glove for its statusSee above
Cyberglove status error: connected =, initialized =The cyberglove reported an invalid statusSee above
Request version failedThe cyberglove initialisation failed to query the glove for its firmware versionSee above
Did not receive complete version message from the gloveExpected version message to be null terminatedThe cyberglove only reported a partial firmware versionSee above
Firmware version reported as 0The cyberglove reported a firmware version of 0See above
Request sensors failedThe cyberglove initialisation failed to query the number of sensors in the gloveSee above
Cyberglove reported 0 sensorsThe cyberglove reported no sensorsSee above
Glove disconnected from CGIULost connection to gloveA protocol error caused the cyberglove driver to disconnect from the gloveRestart the applicationSee above
Failed to actuate [cybertouch]Vibration commands were sent to the glove, but it did not accept themVibration is only supported by the CyberTouch
[fastrak] open failsThe fastrak driver was unable to connect to the specified serial portEnsure the tracker XML configuration is correctEnsure nothing else is using the serial portTurn the device off and on again
[fastrak] set metric mode failsThe fastrak driver was unable to switch the device into metric modeSee above
[fastrak] write fails withThe fastrak driver was unable to write commands to the deviceSee above
[fastrak] read fails withThe fastrak driver was unable to read data from the deviceSee above
[fastrak] sensor out of rangeThe fastrak configuration XML specified a sensor with an index outside of the maximum supported valueEnsure the tracker XML configuration is correct
[fastrak] Error reading fieldThe fastrak driver was unable to read tracking data from the deviceSee above
[handcontroller] open failsThe handcontroller driver was unable to connect to the specified serial portEnsure the tracker XML configuration is correctEnsure nothing else is using the serial port
[handcontroller] read fails withThe handcontroller driver was unable to read data from the deviceSee above
Failed to set station configuration on port, stationThe intersense driver was unable to set the station configuration to Euler anglesRestart the device
Vicon client connection timed outThe vicon driver was unable to connect to the specified hostnameEnsure the Vicon is connected via the networkEnsure the tracker XML is correctEnsure that Vicon Tracker3 is running and configured correctly
SetAxisMapping:Colinear axesLeft handed axesUnknown resultThe vicon driver attempted to set the axis mapping provided by the configuration XML and it was unsuccessful.Ensure the tracker XML is correct
Vicon data stream failing to read segment of subjectVicon data stream failing to read output of deviceThe vicon driver was unable to read tracking data from the specified subjectSee above
Index: -The ZSpace driver encountered an error when configuring a target or display specified by the XMLEnsure the tracker XML is correct